Green Mode |
DoE Level VI, ErP Stage 2, CoC Tier 2 |
No Load Power Consumption Less Than 0.21W |
Model | O/P Voltage | O/P Current ( A ) |
AC150-12CS* | 12 | 10 |
AC150-19CS* | 19 | 7.9 |
AC150-20CS* | 20 | 7.5 |
AC150-24CS* | 24 | 6.25 |
(*) are A or B, means C14, C6 Inlet |
Input |
Voltage | 100-240 VAC |
Line Frequency | 50-60Hz |
Current | 2.8A Max. |
Protection | Internal Primary Current Fuse |
Configuration | IEC60320 C6 / C14 |
Output |
Load Regulation | ± 5% (Typical) |
Ripple | 2% Vp-p Max. for Output Voltage @ Full Load |
Transient Response | 0.5mS for 50% Load Change Typical |
Holdup Time | 10mS @ Full Load |
Protection | Short Circuit Protection/ Over Voltage Protection/ Over Current |
Protection/Over Temperature Protection |
DC Cord | UL2464 / 16AWG / 14AWG |
Ferrite Core | No (Optional) |
Safety Approvals (EN / IEC / 62368) |
| CE / CB / GS |
Electrical |
Dielectric Withstand | 3,000 VAC Primary – Secondary |
Leakage Current | 3.5mA @ 3 Pin |
Efficiency | DoE Level VI, ErP Stage 2, CoC Tier 2 |
EMI Conduction&Radiation | Compliance to EN55032:2015+A1:2020 |
Harmonic Current | Compliance to EN61000-3-2:2019 |
EMS Immunity | Compliance to EN55035:2017+A11:2020 |
MTBF | 300,000 Calculated Hours at 25°C, by Telcordia SR-332 |
Environmental |
Operaturing Temperature | 0 to +40°C |
Storage Temperature | -20 to +80°C |
Relative Humidity | Operating: 20 to 80% RH |
Storage: 10 to 90% RH |
Cooling | Natural Convection Cooling |
Mechanical |
Case Dimension | L 169 x W65 x H43 (mm) |
Weight | 580g (Ref.) |